China Suppliers Factory Lenticular Filter or Depth Stack Cartridge & Capsules for 3M Zeta Plus C Series Replacement

Introducing our advanced cellulose-based depth filtration media, a premier solution manufactured in China. Our high-quality filter media is expertly designed to efficiently retain contaminants through both mechanical entrapment and electrokinetic adsorption. As a trusted supplier, we take pride in providing a product that combines high surface area filter aids seamlessly embedded within a durable cellulose fiber matrix. Our factory utilizes cutting-edge technology to ensure optimal performance and reliability for all your filtration needs. Choose our cellulose filtration media for unparalleled quality and effectiveness.

    Advanced Filtration

    Depth filtration media designed to retain contaminants by mechanical entrapment and electrokinetic adsorption

    This multi-layered depth structure captures particles of various sizes across the entire media depth instead of only on the surface, ensuring thorough and stable filtration efficiency. High contaminant holding capacity for economical filtration and reliable particle removal, effectively extending service life and reducing frequent filter replacement in continuous industrial fluid treatment.

    Lenticular depth stack cartridge filter media
    Safety & Certification

    FDA material compliance

    All filter raw materials fully meet strict FDA food contact safety standards, suitable for food, beverage, pharmaceutical and biopharmaceutical processing. Eases validation and regulatory submissions by providing vital documentation and traceability, supporting smooth compliance with global industrial hygiene and quality supervision requirements.

    FDA compliant lenticular filter capsule
    Plug & Play Design

    Self-contained, single-use disposable capsule and cartridge modules

    These integrated, ready-to-use units need no complex assembly or pre-operation preparation, simplifying on-site operation steps. Reduced labor time for changeouts and elimination of cleaning validation, greatly cutting operational costs and avoiding cross-contamination risks in sensitive fluid processing.

    Single-use disposable capsule module
    Industrial Applications

    Versatile Field Applications

    Pharmaceuticals

    Antibiotics, Cough Syrups, Intravenous Solutions, Growth Media, & Bio process Fluid

    Beverages

    Wine, Beer, Juices, Soft Drinks, & Cider

    Distilled Spirits

    Liquor, Cognac, Cordials

    Food Products

    Syrups, Brines, Broths, Vinegar, Edible Oils, & Sugars

    Cosmetics

    Perfumes, Lotions, Shampoos, Oils, Deodorants, & Colognes

    Product Parameters

    Specifications

    Outside Diameter 8'', 12'', 16''
    Filter sheet material Cellulose fibers, Resins, Perlite, Natural diatomaceous earths, and Etc.,
    Core and Separator Polypropylene (PP)
    O-ring or Gasket Silicone, EPDM, Viton
    Typical Rating H001 = 0.04 - 0.2mµ
    H002 = 0.2 - 0.4µm
    H004 = 0.4 - 0.6µm
    H100 = 1 - 3µm
    H150 = 2 - 5µm
    H200 = 3 - 7µm
    H250 = 10 - 15µm
    H400 = 25 - 30µm
    H500 = 40 - 50µm
    H600 = 50 - 60µm

    Operational Notes & Guidelines

    • 1. Make sure max storage time not exceed 36 months before installation.
    • 2. Sterilization way: Using 80℃ hot purewater sterilization 30 minutes at least and max operation differential pressure is 1bar.
    • 3. When max differential pressure got 2.5bar (23℃) need to change filter.
    • 4. Suggest max operation temperature 60℃ which keeps working well. Max temperature 80-90℃ for a while when steam. Max pressure should be 1kgs for backwashing.
    Frequently Asked Questions

    Frequently Asked Questions

    How does depth filtration with electrokinetic adsorption differ from surface filtration?
    Unlike standard surface filtration that traps particles exclusively on the exterior face, our depth media utilizes a multi-layered matrix that mechanically entraps contaminants throughout its depth while using electrokinetic adsorption to bind sub-micron particles and haze components, providing superior holding capacity and stable efficiency.
    Can these modules be used as direct drop-in replacements for 3M Zeta Plus™ and FILTROX products?
    Yes, these depth stack cartridges and single-use capsules are engineered to match standard 8'', 12'', and 16'' housings, providing equivalent retention performance and physical dimensions for seamless replacement in existing 3M Zeta Plus™ and FILTROX installations.
    Are the materials used in these depth filters FDA compliant?
    All filter raw materials (including cellulose fibers, resins, perlite, and polypropylene components) fully meet FDA food contact regulations, ensuring they are safe for beverage, food, cosmetic, and pharmaceutical manufacturing.
    What is the recommended replacement point for the filter modules?
    Cartridges should be replaced when the differential pressure reaches 2.5 bar at 23℃. Regular differential pressure monitoring ensures that downstream processes remain fully protected from bypass or reduced flow rates.
    What are the recommended sterilization and operating parameters?
    We recommend hot pure water sterilization at 80℃ for at least 30 minutes with a maximum differential pressure of 1 bar. Routine operation runs optimally up to 60℃, with short-term steam resistance up to 80-90℃. Backwashing pressure should not exceed 1 kg.
    What is the maximum shelf life before installation?
    When stored in dry, clean, and sealed factory packaging, the maximum shelf life before installation is up to 36 months.